Products > Air Washer Unit
Single Stage Evaporative Cooling Unit: We offer prevalent quality, Air Washer that work on the rule of cooling the discuss by passing it over water-saturated Celdek pads, water evaporates and results in cooling of air, The cool air is then directed into the ventilated area, Air Washer Unit is a very energy-efficient means of cooling. Air Washer System with cellulose paper pads, cross sectional, specially treated fluid media capable of absorbing and retaining water to provide the maximum cooling efficiencies. The cooling pad is cross corrugated to maximize the mixing of air and water and eliminate water carryover. Air Washer are available from 2000 m3/hr to 3,00,000 m3/hr capacity.
Multi-Stage Evaporative Cooling Unit: Two-stage evaporative units don’t produce humidity levels as high as that produced by industrial single stage evaporative coolers. In the first stage of a two-stage cooler, warm air is pre-cooled indirectly without adding humidity (by passing inside a heat exchanger that is cooled by evaporation on the outside). In the direct stage, the precooled air passes through a water-soaked pad and picks up humidity as it cools. Because the air supply to the second stage evaporator is pre-cooled, less humidity is added to the air (because cooler air can’t hold as much moisture as warmer air). An advanced two-stage evaporative cooler uses 100 percent outdoor air and a variable speed blower to circulate cool air.
Notes:
1. All the dimensions are in mm/inches as specified above.
2. Above dimensions are for 25 mm thick panel. For 50 mm thick panel add 50 mm in above dimensions.
3. Fans selected at 40-50mm static pressure.
4. Wiremesh filter considered 50 mm thick.
Notes:
1. All the dimensions are in mm/inches as specified above.
2. Above dimensions are for 25 mm thick panel. For 50 mm thick panel add 50 mm in above dimensions.
3. Fans selected at 40-50mm static pressure.
4. Wiremesh filter considered 50 mm thick.